Experiment: Anomalous + Normal Zeeman Effect, Hyperfine Structure, Fabry-Pérot Interferometer, Bohr Magneton (230V, 50/60 Hz)

Experiment: Anomalous + Normal Zeeman Effect, Hyperfine Structure, Fabry-Pérot Interferometer, Bohr Magneton (230V, 50/60 Hz), 8001132 [UE5020800-230], Base da Física Atômica
9.540,83 incl. ICMS
New Product
Frete doméstico grátis
A highly versatile experiment from the fascinating world of atomic and quantum physics covering the following topics:
 
  1. Normal Zeeman Effect
  2. Anomalous Zeeman Effect
  3. Hyperfine Structure Splitting
  4. Fabry-Pérot Interferometer
  5. Determination of the Bohr Magneton
 
This experiment investigates the normal and anomalous Zeeman effect using the red (λ = 643.8 nm) and turquoise (λ = 480 nm) cadmium lines. The two etalons in the experiment were optimized for both wavelengths to achieve images with very high resolution. In the case of the anomalous Zeeman effect, line shifts of less than 2 pm are resolved. Additionally, the hyperfine structure splitting of the turquoise Cd line is clearly visible. The Zeeman effect is studied in both transverse (perpendicular) and longitudinal (parallel) configurations relative to an external, variable magnetic field.
Through the theoretical introduction to the Fabry-Pérot etalon, the Bohr magneton can also be experimentally determined in this experiment.
 
Normal Zeeman Effect
The normal Zeeman effect is investigated using the red cadmium line (λ = 643.8 nm). The longitudinal configuration is facilitated by a stepped bore in the pole shoe of the electromagnet. As the light from the Cd lamp passes through the Fabry-Pérot etalon, interference rings are formed, which split into doublets or triplets depending on the direction of the external magnetic field. The linear or circular polarization of the lines is analyzed using a polarization filter and a quarter-wave plate.
The splitting of the interference rings is recorded with a microscope camera. A red filter on the focusing lens enhances the contrast and depth of field for analyzing the Cd lines. The accompanying camera software (for Windows) allows both qualitative observation of the live image and quantitative analysis using screenshots. The experiment is set up on a stable optical precision bench.
 
Anomalous Zeeman Effect
To investigate the anomalous Zeeman effect, the setup for the normal Zeeman effect needs to be modified slightly. The etalon is replaced by a second etalon, and the red filter is substituted with a narrowband bandpass interference filter (FWHM = 10 nm). With this setup, the turquoise cadmium line (λ = 480.0 nm) can be examined. The splitting of the turquoise Cd line in the magnetic field into four (longitudinal) or six (transverse) lines is highly resolved using the Fabry-Pérot etalon. The linear or circular polarization of the lines is analyzed using a polarization filter and a quarter-wave plate.
 
Hyperfine Structure Splitting
In the setup for the anomalous Zeeman effect, the hyperfine structure splitting of the 480 nm cadmium line also becomes visible. In addition to 114Cd (nuclear spin = 0), the Cd lamp contains the isotopes 111Cd and 113Cd, both with a nuclear spin of 1/2. The interaction between nuclear spin and electron leads to hyperfine structure splitting, which in the experiment is visible as up to three additional lines next to the 480 nm line.
 
Fabry-Pérot Interferometer and Determination of the Bohr Magneton
A Fabry-Pérot interferometer is an optical cavity consisting of two plane-parallel mirrors that are partially transparent and have a high reflectivity. The mirrors enclose an optical medium. When the mirrors are at a fixed distance, the setup is also referred to as a Fabry-Pérot etalon. Due to the multiple beam interference, etalons have a very high resolving power.
This part of the experiment is identical to the setup for the normal Zeeman effect. Through the theoretical introduction to the Fabry-Pérot etalon and the investigation of the interference rings, the value of the Bohr magneton can be experimentally determined.



Note:
Experimental manual is available in English and German.

Componentes

Lâmpada de cádmio com acessórios (230V, 50/60 Hz), 1021366 [U8557780-230], Base da Física Atômica

Lâmpada de cádmio com acessórios (230V, 50/60 Hz)

1021366 [U8557780-230]
Preço do artigo
1.348,27 €
Etalão de Fabry-Péro 480 nm, 1025375, Interferômetro

Etalão de Fabry-Péro 480 nm

1025375
Preço do artigo
1.904,00 €
Etalão de Fabry-Pérot 644 nm, 1020903 [U8557590], Interferômetro

Etalão de Fabry-Pérot 644 nm

1020903 [U8557590]
Preço do artigo
1.904,00 €
Núcleo em U modelo D, 1000979 [U8497215], Transformador desmontável D

Núcleo em U modelo D

1000979 [U8497215]
Preço do artigo
186,83 €
Bobina D, 900 espiras, 1012859 [U8497390], Transformador desmontável D

Bobina D, 900 espiras

1012859 [U8497390]
Preço do artigo
127,33 €
Acessório de Electromagnetos para Efeito Zeeman, 1021365 [U8557770], Fundamentos da física atômica

Acessório de Electromagnetos para Efeito Zeeman

1021365 [U8557770]
Preço do artigo
168,98 €
Câmara de microscópio BRESSER MikroCam SP 3.1, 1024060, Microvídeo

Câmara de microscópio BRESSER MikroCam SP 3.1

1024060
Preço do artigo
376,04 €
Lente de 12 mm para Câmera de Microscópio Bresser, 1024059, Óptica no banco ótico

Lente de 12 mm para Câmera de Microscópio Bresser

1024059
Preço do artigo
94,01 €
Vara de Apoio com Rosca de ¼ Polegada, 100 mm, 1025431, Vara de apoio

Vara de Apoio com Rosca de ¼ Polegada, 100 mm

1025431
Preço do artigo
10,71 €

	Filtro de interferência passa-banda, 480 nm, 1025377, Diafragmas, objetos de difração e filtros

Filtro de interferência passa-banda, 480 nm

1025377
Preço do artigo
202,30 €

	Filtro vermelho montado em suporte, 1025376, Diafragmas, objetos de difração e filtros

Filtro vermelho montado em suporte

1025376
Preço do artigo
23,80 €
Lente convergente sobre haste f = 100 mm, 1003023 [U17102], Elementos de arranjo sobre haste

Lente convergente sobre haste f = 100 mm

1003023 [U17102]
Preço do artigo
95,20 €
Filtro de comprimento de onda trimestral no tronco, 1021353 [U22023], Elementos de arranjo sobre haste

Filtro de comprimento de onda trimestral no tronco

1021353 [U22023]
Preço do artigo
249,90 €
Fixação Polarizante, 1021364 [U8557760], Polarização

Fixação Polarizante

1021364 [U8557760]
Preço do artigo
33,80 €
Filtro de polarização sobre haste, 1008668 [U22017], Elementos de arranjo sobre haste

Filtro de polarização sobre haste

1008668 [U22017]
Preço do artigo
160,65 €
Banco óptico de precisão D, 100 cm, 1002628 [U10300], Óptica no banco ótico

Banco óptico de precisão D, 100 cm

1002628 [U10300]
Preço do artigo
397,46 €
Bases para o banco óptico D, conjunto, 1012399 [U103041], Óptica no banco ótico

Bases para o banco óptico D, conjunto

1012399 [U103041]
Preço do artigo
179,69 €
Pé óptico D, 1009733 [U10319], Óptica no banco ótico

Pé óptico D

1009733 [U10319]
Preço do artigo
186,83 €
Cavalete óptico D, 90/36, 1012401 [U103161], Óptica no banco ótico

Cavalete óptico D, 90/36

1012401 [U103161]
Preço do artigo
190,40 €
Cavalete óptico D, 60/36, 1002639 [U103151], Óptica no banco ótico

Cavalete óptico D, 60/36

1002639 [U103151]
Preço do artigo
190,40 €
Cabos de Experimento de Segurança, 75 cm, preto, (2 unid.), 1002849 [U13812], Cabos para experiências

Cabos de Experimento de Segurança, 75 cm, preto, (2 unid.)

1002849 [U13812]
Preço do artigo
15,23 €
Código do Produto: 8001132 [UE5020800-230]
Peso 0.01 kg
Dimensões 0.01 x 0.01 x 0.01 cm
Marca 3B Scientific
  • Secure online payment with SSL
  • Expert advice
  • Easy returns & exchanges
  • International shipping available
Service hotline: +49-40-73966-223
Comprar