Appareil à rayons X (115 V, 50/60 Hz)

Appareil à rayons X (115 V, 50/60 Hz), 1000660 [U192001-US], Physique du röntgen
$ 9 254,00
En cours d’approvisionnement
The experiment chamber is contained in a closed, radiation-proof housing with a transparent synthetic-glass shield. If the synthetic-glass shield is opened, the high-voltage source for the X-ray tube is deactivated automatically. The high-vacuum X-ray tube with a directly heated tungsten cathode and copper anode is positioned in a borosilicate glass chamber with a thinwalled, concave ray emission window. A lead-glass hood with a collimator causes X-rays to emerge in parallel with the experiment plane and provides a shield against scattered radiation. The horizontal counter-tube goniometer consists of a central sample holder and a swiveling arm. In the form of a slide tray, this arm serves as a mount for the Geiger-Müller tube (U19201), ionization chamber (U19208) as well as experimental devices in slide format or on a 5 cm x 5 cm base plate (for example, from U19205, U19206, U19207). The swiveling arm can be rotated manually independently of the sample holder, or at a fixed mutual angle with a ratio of 2:1, for instance, for experiments involving Bragg’s reflection. The device is equipped with angle and millimeter scales, position markings for experimental devices, as well as radiation-proof bushings for cables and hoses. Anode voltage: 20/30 kV, switchable and electronically stabilized Emission current: 0 to 80 μA, continuously adjustable and electronically stabilized Cathode heating: 4 V, 1 A Focal spot: 5x1 mm2 Anode material: Cu Lead-glass collimator: radiation emission aperture with 5-mm dia. Ray divergence: better than 10° Characteristic radiation wavelength: Cu -Kα: 154 pm, Cu -Kβ: 138 pm Counter-tube goniometer: Swiveling ranges: 0°, +10° to +130° and -10° to +130° relative to the ray axis Angular coupling: independent of the sample holder or with a ratio of 2:1 Measurement accuracy of Bragg’s angle: 5 arc minutes Timer: 0 to 55 minutes, continuously adjustable Power consumption: 100 VA Dimensions: X-Ray apparatus: approx. 250 mm x 370 mm dia. X-Ray tube: approx. 100 mm x 32 mm dia. Weight: approx. 9 kg

Vue d'ensemble de toutes les expériences dans lesquelles le produit est utilize

Réf. Article: 1000660 [U192001-US]
Masse 9 kg
Brand 3B Scientific
  • Secure online payment with SSL
  • Expert advice
  • Financing available
  • Easy returns & exchanges
  • International shipping available
Service hotline:
1-888-326-6335
Ajouter au panier

Les clients qui ont déjà acheté cet article ont aussi acheté ces articles:
Support rotatif sur tige, 1003016 [U17001], Composants optiques sur tige
$ 223,00
by 3B Scientific
Paire de patins, 1003044 [U171661], Optique sur banc
$ 164,00
Banc optique U, 600 mm, 1003040 [U17151], Optique sur banc
$ 180,00
by 3B Scientific
Accessoires de cristallographie, 1000666 [U19206], Physique du röntgen
$ 1 598,00
by 3B Scientific Teltron
Basic Set Bragg, 1008508 [U19212], Physique du röntgen
$ 808,00
by 3B Scientific Teltron
Spectroscope plat en métal, 1003184 [U21877], Spectrométrie
$ 176,00
by 3B Scientific
Alimentation CC 0 – 500 V (115 V, 50/60 Hz), 1003307 [U33000-115], Alimentations électriques
$ 1 014,00
by 3B Scientific
Bobine S à 600 spires, 1001000 [U8498070], Transformateur démontable S
$ 56,00
by 3B Scientific
SEE Optique (115 V, 50/60 Hz) , 1008530 [U8503000-115], Kits d'expérimentation - Niveau Supérieur
$ 527,00
by 3B Scientific