X-Ray Apparatus (115 V, 50/60 Hz)

X-Ray Apparatus (115 V, 50/60 Hz), 1000660 [U192001-US], X–Ray Physics
9,603.77
More available in 2-10 days
Free domestic shipping
The experiment chamber is contained in a closed, radiation-proof housing with a transparent synthetic-glass shield. If the synthetic-glass shield is opened, the high-voltage source for the X-ray tube is deactivated automatically. The high-vacuum X-ray tube with a directly heated tungsten cathode and copper anode is positioned in a borosilicate glass chamber with a thinwalled, concave ray emission window. A lead-glass hood with a collimator causes X-rays to emerge in parallel with the experiment plane and provides a shield against scattered radiation. The horizontal counter-tube goniometer consists of a central sample holder and a swiveling arm. In the form of a slide tray, this arm serves as a mount for the Geiger-Müller tube (U19201), ionization chamber (U19208) as well as experimental devices in slide format or on a 5 cm x 5 cm base plate (for example, from U19205, U19206, U19207). The swiveling arm can be rotated manually independently of the sample holder, or at a fixed mutual angle with a ratio of 2:1, for instance, for experiments involving Bragg’s reflection. The device is equipped with angle and millimeter scales, position markings for experimental devices, as well as radiation-proof bushings for cables and hoses. Anode voltage: 20/30 kV, switchable and electronically stabilized Emission current: 0 to 80 μA, continuously adjustable and electronically stabilized Cathode heating: 4 V, 1 A Focal spot: 5x1 mm2 Anode material: Cu Lead-glass collimator: radiation emission aperture with 5-mm dia. Ray divergence: better than 10° Characteristic radiation wavelength: Cu -Kα: 154 pm, Cu -Kβ: 138 pm Counter-tube goniometer: Swiveling ranges: 0°, +10° to +130° and -10° to +130° relative to the ray axis Angular coupling: independent of the sample holder or with a ratio of 2:1 Measurement accuracy of Bragg’s angle: 5 arc minutes Timer: 0 to 55 minutes, continuously adjustable Power consumption: 100 VA Dimensions: X-Ray apparatus: approx. 250 mm x 370 mm dia. X-Ray tube: approx. 100 mm x 32 mm dia. Weight: approx. 9 kg
Item No.: 1000660 [U192001-US]
Weight 9 kg
Brand 3B Scientific
  • 3B Scientific GmbH

    Ludwig-Erhard-Str. 20, 20459 Hamburg
    info@3bscientific.com

    • Secure online payment with SSL
    • Expert advice
    • Easy returns & exchanges
    • International shipping available
    Service hotline: +49-40-73966-223
    Add to cart

    Customers who bought this item also bought these items:
    Rotating Object Holder on Stem, 1003016 [U17001], Optical Components on Stem
    182.71 €
    by 3B Scientific
    Projection Screen, 1000608 [U17130], Optical Components on Stem
    75.02 €
    by 3B Scientific
    Rail Supports, Pair, 1003044 [U171661], Optics with an Optical Bench
    118.58 €
    X-Ray Energy Detector, 1008629 [U10600], Accessories - X-Ray Physics
    1,934.79 €
    Crystallography Set, 1000666 [U19206], X–Ray Physics
    1,222.10 €
    by 3B Scientific Teltron
    Spectroscope in Metal Case, 1003184 [U21877], Spectrophotometer
    162.14 €
    by 3B Scientific
    Digital Spectrometer LD with Absorption Chamber, 1019196 [U22031], Spectrophotometer
    2,351.03 €
    by 3B Scientific
    DC Power Supply 0-500 V (115 V, 50/60 Hz), 1003307 [U33000-115], Power Supplies
    878.46 €
    by 3B Scientific
    DC Power Supply 20 V, 5 A
(115 V, 50/60 Hz), 1003311 [U33020-115], Power Supplies
    342.43 €
    by 3B Scientific
    Bragg Driver, 1012871 [U40207], X–Ray Physics
    3,357.75 €
    Operating Unit for Fine-Beam Tube, 1009948 [U8481425], Accessories – Type D
    2,573.67 €
    by 3B Scientific
    Coil S with 600 Turns, 1001000 [U8498070], Demountable Transformer S
    52.88 €
    by 3B Scientific