Experiment: Anomalous + Normal Zeeman Effect, Hyperfine Structure, Fabry-Pérot Interferometer, Bohr Magneton (230V, 50/60 Hz)

Experiment: Anomalous + Normal Zeeman Effect, Hyperfine Structure, Fabry-Pérot Interferometer, Bohr Magneton (230V, 50/60 Hz), 8001132 [UE5020800-230], Fundamentos de la física atómica
9.540,83 IVA incluido
New Product
Envío doméstico gratuito
A highly versatile experiment from the fascinating world of atomic and quantum physics covering the following topics:
 
  1. Normal Zeeman Effect
  2. Anomalous Zeeman Effect
  3. Hyperfine Structure Splitting
  4. Fabry-Pérot Interferometer
  5. Determination of the Bohr Magneton
 
This experiment investigates the normal and anomalous Zeeman effects using the red (λ = 643.8 nm) and turquoise (λ = 480 nm) cadmium lines. The high-resolution etalon is designed to resolve line shifts of less than 2 pm. Additionally, the hyperfine structure splitting of the turquoise Cd line is clearly visible. The Zeeman effect is studied in both transverse (perpendicular) and longitudinal (parallel) configurations relative to an external, variable magnetic field.
 
Through the theoretical introduction to the Fabry-Pérot etalon, the Bohr magneton can also be experimentally determined in this experiment.
 
Normal Zeeman Effect
The normal Zeeman effect is investigated using the red cadmium line (λ = 643.8 nm). The longitudinal configuration is facilitated by a stepped bore in the pole shoe of the electromagnet. As the light from the Cd lamp passes through the Fabry-Pérot etalon, interference rings are formed, which split into doublets or triplets depending on the direction of the external magnetic field. The linear or circular polarization of the lines is analyzed using a polarization filter and a quarter-wave plate.
The splitting of the interference rings is recorded with a microscope camera. A red filter on the focusing lens enhances the contrast and depth of field for analyzing the Cd lines. The accompanying camera software (for Windows) allows both qualitative observation of the live image and quantitative analysis using screenshots. The experiment is set up on a stable optical precision bench.
 
Anomalous Zeeman Effect
To investigate the anomalous Zeeman effect, the setup for the normal Zeeman effect needs to be modified slightly. The etalon is replaced by a second etalon, and the red filter is substituted with a narrowband bandpass interference filter (FWHM = 10 nm). With this setup, the turquoise cadmium line (λ = 480.0 nm) can be examined. The splitting of the turquoise Cd line in the magnetic field into four (longitudinal) or six (transverse) lines is highly resolved using the Fabry-Pérot etalon. The linear or circular polarization of the lines is analyzed using a polarization filter and a quarter-wave plate.
 
Hyperfine Structure Splitting
In the setup for the anomalous Zeeman effect, the hyperfine structure splitting of the 480 nm cadmium line also becomes visible. In addition to 114Cd (nuclear spin = 0), the Cd lamp contains the isotopes 111Cd and 113Cd, both with a nuclear spin of 1/2. The interaction between nuclear spin and electron leads to hyperfine structure splitting, which in the experiment is visible as up to three additional lines next to the 480 nm line.
 
Fabry-Pérot Interferometer and Determination of the Bohr Magneton
A Fabry-Pérot interferometer is an optical cavity consisting of two plane-parallel mirrors that are partially transparent and have a high reflectivity. The mirrors enclose an optical medium. When the mirrors are at a fixed distance, the setup is also referred to as a Fabry-Pérot etalon. Due to the multiple beam interference, etalons have a very high resolving power.
This part of the experiment is identical to the setup for the normal Zeeman effect. Through the theoretical introduction to the Fabry-Pérot etalon and the investigation of the interference rings, the value of the Bohr magneton can be experimentally determined.



Note:
Experimental manual is available in English and German.

Componentes

Lámpara de cadmio con accesorios (230V, 50/60 Hz), 1021366 [U8557780-230], Fundamentos de la física atómica

Lámpara de cadmio con accesorios (230V, 50/60 Hz)

1021366 [U8557780-230]
Precio del artículo
1.348,27 €
Etalón Fabry-Perot 480 nm, 1025375, Interferómetro

Etalón Fabry-Perot 480 nm

1025375
Precio del artículo
1.904,00 €
Fabry-Perot-Etalon 644 nm, 1020903 [U8557590], Interferómetro

Fabry-Perot-Etalon 644 nm

1020903 [U8557590]
Precio del artículo
1.904,00 €
Núcleo en U modelo D, 1022663, Transformador desmontable D

Núcleo en U modelo D

1022663
Precio del artículo
216,58 €
Bobina D, 900 espiras, 1012859 [U8497390], Transformador desmontable D

Bobina D, 900 espiras

1012859 [U8497390]
Precio del artículo
127,33 €
Electroimán accesorio para efecto Zeeman, 1021365 [U8557770], Fundamentos de la Física atómica

Electroimán accesorio para efecto Zeeman

1021365 [U8557770]
Precio del artículo
168,98 €
Cámara de Microscopio BRESSER MikroCam SP 3.1, 1024060, Microvídeo

Cámara de Microscopio BRESSER MikroCam SP 3.1

1024060
Precio del artículo
376,04 €
Lente de 12 mm para la cámara de microscopía Bresser, 1024059, Óptica en el banco óptico

Lente de 12 mm para la cámara de microscopía Bresser

1024059
Precio del artículo
94,01 €
Stainless Steel Rod with ¼ inch Thread, 100 mm, 1025431, Varilla de soporte

Stainless Steel Rod with ¼ inch Thread, 100 mm

1025431
Precio del artículo
10,71 €
Bandpass Interference Filter 480nm, 1025377, Diafragmas, Elementos de difragción y Filtros

Bandpass Interference Filter 480nm

1025377
Precio del artículo
202,30 €
Filtro de color rojo en la montura, 1025376, Diafragmas, Elementos de difragción y Filtros

Filtro de color rojo en la montura

1025376
Precio del artículo
23,80 €
Lente convexa sobre mango f = 100 mm, 1003023 [U17102], Componentes ópticas sobre mango

Lente convexa sobre mango f = 100 mm

1003023 [U17102]
Precio del artículo
95,20 €
Filtro de cuarto de onda en varilla, 1021353 [U22023], Componentes ópticas sobre mango

Filtro de cuarto de onda en varilla

1021353 [U22023]
Precio del artículo
249,90 €
Accesorio de polarización, 1021364 [U8557760], Polarización

Accesorio de polarización

1021364 [U8557760]
Precio del artículo
33,80 €
Filtro de polarización sobre mango, 1008668 [U22017], Componentes ópticas sobre mango

Filtro de polarización sobre mango

1008668 [U22017]
Precio del artículo
160,65 €
Banco óptico de precisión D, 1000 mm, 1002628 [U10300], Óptica en el banco óptico

Banco óptico de precisión D, 1000 mm

1002628 [U10300]
Precio del artículo
397,46 €
Base para banco óptico D, 1012399 [U103041], Óptica en el banco óptico

Base para banco óptico D

1012399 [U103041]
Precio del artículo
179,69 €
Pie óptico D, 1009733 [U10319], Óptica en el banco óptico

Pie óptico D

1009733 [U10319]
Precio del artículo
186,83 €
Jinetillo óptico D, 90/36, 1012401 [U103161], Óptica en el banco óptico

Jinetillo óptico D, 90/36

1012401 [U103161]
Precio del artículo
190,40 €
Jinetillo óptico D, 60/36, 1002639 [U103151], Óptica en el banco óptico

Jinetillo óptico D, 60/36

1002639 [U103151]
Precio del artículo
190,40 €
Par cables de experimentación de seguridad 75cm, 1017718 [U13816], Cables de experimentación

Par cables de experimentación de seguridad 75cm

1017718 [U13816]
Precio del artículo
17,02 €
Cables de experimentación de seguridad, 75 cm, par de, 1002849 [U13812], Cables de experimentación

Cables de experimentación de seguridad, 75 cm, par de

1002849 [U13812]
Precio del artículo
15,23 €
Artículo No.: 8001132 [UE5020800-230]
Weight 0.01 kg
Dimensions 0.01 x 0.01 x 0.01 cm
Brand 3B Scientific
  • Secure online payment with SSL
  • Expert advice

Service hotline: 1-888-326-6335
Agregar al carrito